S3F80KB_AN_REV 0.00 (Preliminary Spec) IR REMOTE CONTROLLER
5
1.2 IR SIGNAL
All remote controller manufactures define IR protocol which is specified on their products or companies. This
application note describes example of IR protocol. This IR protocol determines the bit 1 and 0 by pulse distance.
Carrier freuqeuncy is 37.9kHz and the frame period is 108ms. Leader is the start of frame. Following custom code
is remote controller manufacture's customer code. It consists of 2 Bytes which is same each bytes. Data code and
Data bar which is complemented Data code is sequentially transmitted. Last the end bit is transmitted.
The example protocol is shown Figure 1 below. (Custom code: 0x07H, Datacode: 0x02H)
Leader Custom Custom Data Data
End
Bit
...
4.5ms 4.5ms
.. ..
0.56ms 0.56ms 0.56ms 1.69ms
8.8us 17.6us
carrier frequency: 37.9kHz
Data : 0
Data : 1
Leader
108ms 108ms
LSB MSB LSB MSB LSB MSB LSB MSB
Figure 1. IR Signal