RBS3202 Test with CMU300 and RNC/Iub SIM
1CM56_E 11 Rohde & Schwarz
To select the CDP measurement unit use softkeys Code Dom.
Power / Unit.
To measure the code domain power (CDP) of a code channel,
activate the marker functions (softkeys Marker / Ref. / Rel. 1 / Rel.
2).
To start the peak code domain error (PCDE) measurement use
softkeys Application / Peak Code Dom. Error.
Receiver test
NH RNC/Iub Simulator:
Start the BER Test menu
R&S CMU300:
Switch to the Generator menu (softkey Connect. Control / tab
Generator) and enter the following settings (press the Generator
softkey at the foot of the screen twice).